Chemical/Pressure/
Temperature Resistance
All tests performed on Scotchkote
134 coating applied over a 1 mil
(25,4 microns) phenolic primer.
Liquid phase for all test conditions
33% kerosene, 33% toluene,
34% brine solution 5% NaCI.
Operating Results
Test Conditions

Gas

Phase

Results

Autoclave, 120°F (49°C)
48 hours 1500 psi (10.3MPa)
99.5%
0.5%
CO
H2S
Excellent adhesion, no coating loss or blisters in aqueous, hydrocarbon or gas phase
Autoclave, 150°F (66°C)
48 hours 2200 psi (15.2 MPa)
89%
12%
8%
CH4
CO2
H2S
Excellent adhesion, no coating loss or blisters in aqueous, hydrocarbon or gas phase.
Autoclave, 200°F (93°C),
42 hours 3300 psi (22.8 MPa)
86%
8%
6%
CH4
CO2
H2S
Excellent adhesion, no coating loss or blisters in aqueous, hydrocarbon or gas phase.
Autoclave, 300°F (149°C),
24 hours 3000 psi (20.7 MPa)
90%
10%
Trace
CH4
CO2
H2S
Excellent adhesion, no coating loss or blisters in aqueous, hydrocarbon or gas phase.